What to check before the soft starter is powered on?

2023-05-20 11:27:04

Soft starter is a novel motor control device that integrates motor soft start, soft stop, light load energy saving and multiple protection functions. It is called Soft Starter abroad. The domestic soft starter is the most famous Heping hps2 series soft starter. Its main composition is a three-phase parallel thyristor and its electronic control circuit connected in series between the power supply and the controlled motor.


The soft starter we use needs to be powered on. Generally, we need to check before power on before use. Let's take a look with the editors below to see which ones to check:


First, check the wiring


1. Check whether the wiring is correctly connected in accordance with the requirements of the product instruction manual, especially pay attention not to connect the output terminals (U, V, W) to the three-phase power supply.


2. Check whether the installation is normal and whether the grounding is correct and reliable. Especially for the control circuit wiring (such as the given signal line and feedback signal line on the input side, the frequency signal line and current signal line on the output side, the switch signal control line, etc.), it is necessary to keep away from the main circuit (more than 100mm) and shield Anti-interference measures. The shield of the cable should be connected to the common end (COM) of the control circuit near the inverter. Do not connect to the ground (PE) of the inverter. The other end of the shield should be suspended.


3. Check whether the brake unit wiring is correct. When connecting an external braking resistor (some inverters have a built-in braking resistor, when the capacity is insufficient, an external braking resistor is required), first remove the wiring of the built-in braking resistor from the P (+) and DBd terminals, and The wire end is insulated, and then the external braking resistor is connected to P (+) and DB. It is required that the wiring length is less than 5M, and twisted pairs are used.


4. Check whether the DC reactor wiring is correct. Note: Short-circuit conductors are connected to the connection terminals P1 and P (+) when leaving the factory. When using a DC reactor, this short-circuit conductor should be removed; if a DC reactor is not used, the short-circuit conductor can be connected at both ends of the reactor.


2. Check AC power. For three-phase inverters, the three-phase AC power supply voltage should be within the allowable range (such as 340-440v). Overvoltage and undervoltage are strictly prohibited.


Third, check the motor


1. Use a 500V-1000V megohmmeter to measure the insulation resistance of the motor winding to the shell, which should not be less than 5 megohms. If the insulation resistance is less than 2 megohms or the winding has been in contact with the shell, it is strictly prohibited to use the inverter. Otherwise, the inverter will be damaged.


2. Measure the DC resistance between the three windings of the motor, which should be balanced in three phases, and the resistance between the windings of each phase is ohms. If the resistance is too small or zero, it means that there is a short circuit in the motor winding, and it is strictly forbidden to use it.


In general, when we check the power of the soft starter, we also need to pay attention to the above points to reduce failures due to power problems during use.


通用變頻器


label

QR code

The public,

Mobile station
The public, Mobile station

Contact

未標(biāo)題-8.png 0755-81719517
未標(biāo)題-10.png0755-81719530 未標(biāo)題-11.pngamb@ambition.com.cn
未標(biāo)題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

Navigation

Home          About

Product      Case

Solution      Service

Job      News

Contact          

Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
主站蜘蛛池模板: 亚洲一区二区三区不卡视频 | 狠狠色丁香久久婷婷综合五月| 日日噜噜夜夜狠狠视频buoke| h视频在线看| 男人的天堂五月天| 夜夜操操| 精品福利视频网| 天堂激情网| 国产高清在线精品| 清纯唯美亚洲综合五月天| 91啦在线视频| 看黄网站免费| 亚洲欧美国产视频| 果冻天美a∨传媒| 四虎4hu永久免费国产精品| 福利一区二区在线| 欧洲成人在线| 91视频免费观看| 麻豆作品| 亚洲一区欧美日韩| 精品久久免费视频| 五月天激情综合网| 国产精品真实对白精彩久久| 日韩精品第一区| www.日本| 欧美日韩一区二区三区在线播放| 中文字幕一区二区三区 精品| 久久精品午夜视频| 亚洲精品91| 国内特级毛片| 四虎精品福利视频精品| 国产成人精品一区二区三在线观看 | 日韩精品在线第一页| 成年人免费黄色| 欧美图片自拍偷拍| 91蜜桃传媒一二三区| 美国农夫激情在线综合| 亚洲一区二区三区亚瑟| 精品国产中文一级毛片在线看| 天天添天天操| 国产精品综合在线|